Skip to content
EES

📍 Riyadh, Riyadh Province

Crane Proof Load Testing (Water Bag, Dead-Weight & Pull-Out) in Riyadh

Crane proof load testing shows that a crane, davit, lifting beam, pad-eye or anchor carries the specified test load without damage or permanent deformation. The test load is set by the governing standard and your client's scheme, normally above the rated load. EES applies it by water bag, certified dead weights or hydraulic pull, verifies it on a calibrated load cell or against documented weight mass, and records the result against a written procedure. The capital drives Vision 2030 with giga-projects, metro, urban developments and a vast contractor base.

Crane Proof Load Testing in Riyadh: local context

Steel erection and heavy lifting in Riyadh typically call for load tests on cranes and proof load tests on lifting beams before the main lifts begin, while welded structures and pressure piping fabricated in workshops in 2nd Industrial City Riyadh often need NDT before they ship to site. Summer heat affects when outdoor loading and surface preparation can be done safely, so EES can schedule that work for cooler hours and hand over documented test records and NDT reports.

What we deliver in Riyadh

  • ✓Water-bag load testing of mobile, overhead, gantry and jib cranes, davits and lifting beams, with bags sized to the test load and filled in controlled stages
  • ✓Dead-weight testing with test weights of known, documented mass for hoists, overhead cranes and workshop or yard lifting equipment where weights can be positioned
  • ✓Pull-out and proof tests of anchors, bolts, pad-eyes, lifting lugs, deck fittings and tie-down points using a calibrated hydraulic jack and reaction frame
  • ✓Applied load read on a calibrated load cell or inline dynamometer in the load path for water-bag and hydraulic tests, and checked against certified masses for dead-weight tests, so the recorded value is a measured force and not an estimate from bag volume
  • ✓Written test procedure, risk assessment, lift plan and exclusion zone, with the test run under a competent person and a clear stop-work authority
  • ✓Hold-time, brake-hold, deflection and structural checks, with a visual examination before and after the test and NDT of critical welds where the procedure calls for it
  • ✓Proof testing of personnel baskets, lifting frames and spreaders where the client scheme requires it, a check that the rated capacity (SWL / WLL) marked on the item matches the test, and re-test after repair, modification or relocation

Standards

  • ✓ASME B30.2 (overhead and gantry cranes), B30.5 (mobile cranes) and B30.20 (below-the-hook lifting devices), as applicable to the equipment tested
  • ✓EN 13000 (mobile cranes)
  • ✓Requirements such as the current revisions of Saudi Aramco GI 7.030 (cranes and lifting equipment) and GI 7.027 (personnel baskets)
  • ✓ASTM E488 (strength of anchors in concrete) and manufacturer test requirements

Documentation

  • ✓Proof load test certificate identifying the item and stating applied load, hold time and result
  • ✓Test procedure, method statement and signed test record sheet
  • ✓Load cell and test-weight calibration references
  • ✓Post-test inspection findings, with NDT reports where specified

Read the full Crane Proof Load Testing service overview →

FAQs

Do you provide Crane Proof Load Testing in Riyadh?+

Yes. EES provides Crane Proof Load Testing at client sites in Riyadh, including Sudair City, 2nd Industrial City Riyadh and King Salman Park. Contact us with your requirement and we will confirm scope and scheduling.

Which standards and documents apply to Crane Proof Load Testing in Riyadh?+

Work in Riyadh is aligned with the following standards and references: ASME B30.2 (overhead and gantry cranes), B30.5 (mobile cranes) and B30.20 (below-the-hook lifting devices), as applicable to the equipment tested; EN 13000 (mobile cranes); Requirements such as the current revisions of Saudi Aramco GI 7.030 (cranes and lifting equipment) and GI 7.027 (personnel baskets); ASTM E488 (strength of anchors in concrete) and manufacturer test requirements. On completion you receive: Proof load test certificate identifying the item and stating applied load, hold time and result; Test procedure, method statement and signed test record sheet; Load cell and test-weight calibration references.

Should I choose a water bag load test or dead-weight testing?+

Water bags suit most field tests because they are filled in controlled stages, dumped quickly and reach large loads without hauling heavy blocks, but they need a water supply and somewhere to drain. Dead weights with a mass certificate suit workshops and yards where the weights are on hand and the load is modest. Fixed anchors, pad-eyes and lifting points that cannot hang a load are tested by pull-out with a calibrated hydraulic jack and reaction frame.

What test load and hold time do you apply?+

The test factor and hold time come from the governing standard, the crane manufacturer and your client's scheme, and they differ between mobile cranes, overhead cranes, davits and lifting beams. The test load is commonly set above the rated load. We write the figures into a method statement with the acceptance criteria and agree it with you before the test.

Book Crane Proof Load Testing in Riyadh